Jump to content

AMBEO VR Mic: Difference between revisions

Neo222 (talk | contribs)
No edit summary
Neo222 (talk | contribs)
No edit summary
Line 35: Line 35:


==Specifications==
==Specifications==
 
{| class="wikitable sortable" style= "text-align: center"
|-
!Part
!Spec
|-
|Dimensions (L x D)||215 x 49/25 mm
|-
|Weight ||2.34lbs
|-
|Transducer Principle||Pre-polarized condenser mic
|-
|Pickup Pattern||"4 cardioids arranged in A format
FLU – Front-Left Up
FRD – Front-Right Down
BLD – Back-Left Down
BRU – Back-Right Up”
|-
|Mixing to B-Format||"W, X, Y, and Z
W – FLU + FRD + BLD + BRU
X – FLU + FRD - BLD – BRU
Y – FLU - FRD + BLD – BRU
Z – FLU - FRD - BLD + BRU”
|-
|Frequency Response||20Hz to 20kHz
|-
|Matrix Reference||Center of the capsule holder
|-
|Sensitivity||"31 mV/Pa (-30 dBV)”
|-
|Nominal Impedance||200 ohms (approx.)
|-
|Min. Terminating Impedance||1000 ohms
|-
|Equivalent Noise Level||"18 dB-A as per IEC 61672-1
27 dB CCIR as per CCIR 468-3”
|-
|Maximum Sound Pressure Level||130 dB(A) for 1kHz
|-
|Power Supply||4 x phantom powering (P48) as per IEC 61938 (48 ± 4 V), 3.5 mA each
|-
|Mic Connector||DIN12M (use enclosed adapter cable to convert to 4x XLR3M)
Polarity||Pin1 (GND), Pin2 (+), Pin3 (-)
|-
|Operating Temperature||"-10 to 55-degree Celsius
14 to 131-degree Fahrenheit”
|-
|Storage Temperature||"-20 to 70-degree Celsius
-4 to 158-degree Fahrenheit”
|-
|Relative Humidity||Max 90% at 104-degree Fahrenheit / 40-degree Celsius
|-
|}


==Inside the Box==
==Inside the Box==